The broker sends three listings. One is 15,000 square feet, one is 20,000, one is 25,000 with better clear height. Everybody in the meeting has an opinion. Nobody has done the math from the pallets up.
My position: square feet is the last number you work out, not the first. Start with how many pallets you hold on your worst week and build out from there.
How the math works
For selective pallet rack, the chain goes like this:
- Positions needed = peak pallets / target rack utilization
- Bays = positions / (pallets per level x levels)
- Storage square feet = bays x bay width x (rack depth + half the flue + half the aisle)
- Building square feet = storage / (1 - share for everything else)
- Clear height = (levels - 1) x (load height + beam allowance) + load height + sprinkler clearance
Step 3 uses half the flue and half the aisle because back-to-back rows share the flue and each aisle serves two rack faces.
The worked example
Start with 1,000 pallets at peak. The rest are common starting points, not rules:
- 4 rack levels, floor included, 2 pallets per level
- Run the racks at 85% full
- Bay pitch 99 inches (8.25 ft), rack depth 42 inches, 6 inch flue
- 12 ft aisles
- 35% of the building for docks, staging, packing and offices
- 60 inch loads, 10 inches per level for beam and lift-off, 18 inches below the sprinklers
The math:
- Positions: 1,000 / 0.85 = 1,176.5, so 1,177
- Bays: each bay holds 4 x 2 = 8. 1,177 / 8 = 147.1, so 148 bays (1,184 positions built)
- Depth per bay: 3.5 + 0.25 + 6 = 9.75 ft
- Storage area: 148 x 8.25 x 9.75 = 11,905 sq ft
- Building: 11,905 / 0.65 = 18,315 sq ft, of which 6,410 is docks, staging, pack and office
- Clear height: 3 x (60 + 10) + 60 + 18 = 288 inches, or 24 ft
That works out to about 64.6 pallet positions per 1,000 square feet of building.
So of those three listings, the 15,000 holds the racks but not the docks and the pack line. The 20,000 fits with some room. The 25,000 is a question of whether you grow into it before the lease is up.
Common mistakes
Sizing to the average. Average inventory is what you hold in March. The building has to hold November. Use your peak week.
Planning to 100% full. A full rack is a slow rack. Putaway hunts for open slots and pickers dig. 85% is a working number. The math reserves the gap on purpose.
Forgetting everything that is not rack. Docks, staging lanes, a pack line, returns, a break room. 35% is a starting point. A pack-heavy ecommerce floor often needs more.
Picking aisle width last. Aisle width comes from the lift truck. Under about 10 ft you are usually into narrow aisle reach trucks or turret trucks, not counterbalance forklifts. Decide the truck, then the aisle.
Reading clear height off the listing. Clear height is to the lowest obstruction, and your fire code and sprinkler design set the real limit. The 24 ft here is a minimum to ask for, not a promise you can rack to it.
Tomorrow morning
Pull your on-hand pallet count for every week of the last 12 months. Find the highest week. That is your peak, and it is the only number you should give the broker.
Then run it through the free warehouse space calculator and change one assumption at a time. Try a fifth rack level, then a narrower aisle, and see what each one does to the building.
OpsBox knows every rack, bin and pallet position on your floor and what is in it, live. You see how full you really are before you sign a bigger lease.